nickerop.blogg.se

Windows 2011 sbs end of life
Windows 2011 sbs end of life







  1. #WINDOWS 2011 SBS END OF LIFE MAC OS#
  2. #WINDOWS 2011 SBS END OF LIFE INSTALL#
  3. #WINDOWS 2011 SBS END OF LIFE UPGRADE#

"Failed to run custom action DbUpgrade./MDMCore-Linux-x86_64.sh: 1079: Error '1' occured while running custom action DbUpgrade."

#WINDOWS 2011 SBS END OF LIFE UPGRADE#

"Failed" -> error : ReadUpgradeStatus: Upgrade infrastructure task failed: Command failed (exit code: 1)" Upgrading the MDM appliance to version 6.5 using Client Task ends with an error:.Solution: Revert DB from backup and perform the upgrade again.

windows 2011 sbs end of life

It is forbidden to reboot the computer during this process, as it will result in a corrupted database. In specific cases, when the database is too large, or hardware is not powerful enough (slow HDD, not enough RAM) it could take a longer time to complete. Even though the MSI is already upgraded to version 6.5, the upgrade of the database is still in progress.

  • When performing an upgrade of previous versions of ESET Remote Administrator to version 6.5, it might happen, that it is not possible to connect to ERA Server.
  • Solution: This is a database-related issue - contact ESET technical support to resolve.
  • MDM can stop working after a mobile device's static object is removed (for example, if a task or policy is removed from the device).
  • Installing ERA Agent on macOS Sierra (10.12) requires root privileges.
  • #WINDOWS 2011 SBS END OF LIFE INSTALL#

    Solution: Uninstall the previous version of RD Sensor, and then install a new RD Sensor from the repository.

  • Versions of ESET Rogue Detection Sensor included in previous versions (6.1.33.0 and earlier) of ERA cannot be upgraded to the version included in ERA 6.4.29.0.
  • Some Android devices might have the same device identification, and those devices will fail to enroll into MDC.
  • Mobile Device Connector (MDC) requires unique device identification to be able to process device enrollment correctly since the internal structures of MDC need unique device identification.
  • windows 2011 sbs end of life

    The Agent cannot connect, because OS X cannot accept the Certificate Authority.

    #WINDOWS 2011 SBS END OF LIFE MAC OS#

    It is not possible to parse a date variable from the Certificate Authority on Mac OS X.

  • Certificates with validity ending after the year 2037 are not supported on Mac OS X.
  • It is not possible to use Windows Phone for two-factor authentication if ESET Remote Administrator is a part of the domain and domain user is provisioned.
  • windows 2011 sbs end of life

    Solution: Set the Mobile Device Connector service Startup type to “Manual”, then restart the service from within Services and run the upgrade procedure again.









    Windows 2011 sbs end of life